Performance

Environment Plants management Status

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building11,426
  • Pavement29,415
  • Green23,313
Person in charge
  • Personnel : Mingyu Mun
  • E-mail : mg.mun@samsung.com
  • TEL : +82-31-288-4981
Giheong

단위 : 명

  • building17.8
  • Pavement45.9
  • Green36.3
  • Area Unit(Unit: ㎡)
    • building : 14,509
      Pavement : 29,415
      Green : 23,313
  • Person in charge
    • Personnel : Mingyu
      E-mail : mg.mun@samsung.com
      TEL : +82-31-288-4981
Location

Situated within greens of an urban area technically. 1.2km away from this lies the Shingal reservoir and residential areas. 2km away are the Kihung I.C. and Shingal I.C. After going through biological and chemical teratment, water discharge joins the Gongse stream through Singal reservoir and the Osan stream and reaches West sea.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 398
Water(kiloton) : 129
Recycle Water(kiloton) : 1
Toxic chemicals(ton) : 39
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 20
Water discharge(kiloton) : 29
Waste Recycling(ton) : 959
Waste Landfill(ton) : 3
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 20 Average 2.8
Water pollutants(ppm) COD Legal limit 40 Average 3.7
Water pollutants(ppm) SS Legal limit 20 Average 1.1
Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building17,400
  • Pavement26,578
  • Green7,400
Person in charge
  • Personnel : ByungJun Noh
  • E-mail : byungjun.noh@samsung.com
  • TEL : +82-31-596-3205
Uiwang

단위 : 명

  • building33.9
  • Pavement51.7
  • Green14.4
  • Area Unit(Unit: ㎡)
    • building : 17,400
      Pavement : 26,578
      Green : 7,400
  • Person in charge
    • Personnel : ByungJun Noh
      E-mail : byungjun.noh@samsung.com
      TEL : +82-31-596-3205
Location

It is located in a general industrial complex in a city and a residential area is formed 0.5km away from the plant. Ui-Wang IC off Ui-Wang to Gwa-Cheon expressway is about 2km away. The entire waste water is disposed on consignment, and household sewage is released into Ui-Wang municipals sewage treatment plant.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 334
Water(kiloton) : 102
Recycle Water(kiloton) : 0
Toxic chemicals(ton) : 0
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 17
Water discharge(kiloton) : 102
Waste Recycling(ton) : 1,779
Waste Landfill(ton) : 222
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 200 Average N/A
Air pollutants(ppm, mg/㎥) SOx Legal limit 500 Average N/A
Air pollutants(ppm, mg/㎥) Dust Legal limit 100 Average 3.0
Air pollutants(ppm, mg/㎥) HF Legal limit 3 Average N/A
Air pollutants(ppm, mg/㎥) HCl Legal limit 6 Average N/A

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building7,486
  • Pavement13,242
  • Green2,097
Person in charge
  • Personnel : HyoungGi Joo
  • E-mail : hyounggi.joo@samsung.com
  • TEL : +82-31-8061-5790
Suwon R&D

단위 : 명

  • building32.8
  • Pavement58.0
  • Green9.2
  • Area Unit(Unit: ㎡)
    • building : 7,486
      Pavement : 13,242
      Green : 2,097
  • Person in charge
    • Personnel : HyoungGi Joo
      E-mail : hyounggi.joo@samsung.com
      TEL : +82-31-8061-5790
Location

It is located at Electronic Material R&D Complex (in Mae-Tan Dong, Yeoung-Tong Gu, Suwon City, Gyeonggi Do, ROK). The center hosts Samsung Group subsidiaries specialized in material businesses such as Samsung Electronics, Samsung Fine Chemicals as well as Samsung SDI, and supports the R&D activities for the development of materials not products or parts. Filthy/waste water is jointly disposed at waste water treatment facility of Samsung Electronics’ Digital City before being released into a nearby river (i.e Won-Cheon River).

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 359
Water(kiloton) : 54
Recycle Water(kiloton) : 0
Toxic chemicals(ton) : 0
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 19
Water discharge(kiloton) : 0
Waste Recycling(ton) : 326
Waste Landfill(ton) : 0

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building124,912
  • Pavement91,475
  • Green9,022
Person in charge
  • Personnel : Jihye Park
  • E-mail : jihyea00.park@samsung.com
  • TEL : +82-41-560-3270
Cheonan

단위 : 명

  • building55.4
  • Pavement50.6
  • Green4.0
  • Area Unit(Unit: ㎡)
    • building : 124,912
      Pavement : 91,475
      Green : 9,022
  • Person in charge
    • Personnel : Jihye Park
      E-mail : jihyea00.park@samsung.com
      TEL : +82-41-560-3270
Location

Situated within the Cheonan industrial complex 3, 200m away from nearest residential areas. 2km away lie the Upsung reservoir and Notae mountain. The plant runs biological and chemical treatments for company sewage. Water discharge moves to the sewerage treatment facility in Area 3 and flows through the Cheonan stream and the Gokgyo stream to the West sea.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 4,390
Water(kiloton) : 1,737
Recycle Water(kiloton) : 300
Toxic chemicals(ton) : 9,627
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 178
Water discharge(kiloton) : 8,093
Waste Recycling(ton) : 15,740
Waste Landfill(ton) : 422
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 200 Average 1.7
Air pollutants(ppm, mg/㎥) SOx Legal limit 500 Average N/A
Air pollutants(ppm, mg/㎥) Dust Legal limit 50 Average 0.8
Air pollutants(ppm, mg/㎥) THC Legal limit 40 Average 0.2
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 280 Average 10.2
Water pollutants(ppm) COD Legal limit 320 Average 12.8
Water pollutants(ppm) SS Legal limit 300 Average 10.8

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building15,239
  • Pavement19,969
  • Green9,899
Person in charge
  • Personnel : Sung Hee Lee
  • E-mail : shsrcm.lee@samsung.com
  • TEL : +82-43-200-0210
Cheongju

단위 : 명

  • building20.3
  • Pavement66.5
  • Green13.2
  • Area Unit(Unit: ㎡)
    • building : 15,239
      Pavement : 19,969
      Green : 9,899
  • Person in charge
    • Personnel : Sung Hee Lee
      E-mail : shsrcm.lee@samsung.com
      TEL : +82-43-200-0210
Location

The plant belongs to an industrial complex in an urban area. Within 1 km, there are Mi-Ho river and residential area, and O-Chang IC off Jung-Bu expressway is about 3km away. The waste water disposed from the plant is released into O-Chang Environmental Business Center before being discharged in Mi-Ho river.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 786
Water(kiloton) : 956
Recycle Water(kiloton) : 469
Toxic chemicals(ton) : 2,231
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 39
Water discharge(kiloton) : 487
Waste Recycling(ton) : 6,298
Waste Landfill(ton) : 13
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 200 Average N/A
Air pollutants(ppm, mg/㎥) SOx Legal limit 500 Average N/A
Air pollutants(ppm, mg/㎥) Dust Legal limit 100 Average 6.0
Air pollutants(ppm, mg/㎥) HF Legal limit 3 Average N/A
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 100 Average 25.0
Water pollutants(ppm) COD Legal limit 100 Average 18.0
Water pollutants(ppm) SS Legal limit 100 Average 21.0

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building181,320
  • Pavement17,840
  • Green43,960
Person in charge
  • Personnel : Jeong Hwan Nam
  • E-mail : jh.nam@samsung.com
  • TEL : 054-468-2240
Gumi

단위 : 명

  • building74.6
  • Pavement7.3
  • Green18.1
  • Area Unit(Unit: ㎡)
    • building : 181,320
      Pavement : 17,840
      Green : 43,960
  • Person in charge
    • Personnel : Jeong Hwan Nam
      E-mail : jh.nam@samsung.com
      TEL : +82-54-468-2240
Location

Samsung SDI’s Gumi plant belongs to 1st industrial complex of Gumi city. Im-Eun Dong residential area is formed facing the plant’s South Gate, and South Gumi IC and Gumi IC off Gyeongbu Expressway, South Korea’s prime industrial expressway, are only 5 KM away from the plant. The disposed waste water is released into the municipal terminal sewage disposal plant after flowing through Kwang-Pyung River.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 599
Water(kiloton) : 509
Recycle Water(kiloton) : 110
Toxic chemicals(ton) : 1,662
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 30
Water discharge(kiloton) : 465
Waste Recycling(ton) : 5,281
Waste Landfill(ton) : 12
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 200 Average N/A
Air pollutants(ppm, mg/㎥) SOx Legal limit 400 Average 2.6
Air pollutants(ppm, mg/㎥) Dust Legal limit 50 Average 0.8
Air pollutants(ppm, mg/㎥) HF Legal limit 3 Average N/A
Air pollutants(ppm, mg/㎥) HCI Legal limit 6 Average 0.6
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 80 Average 0.9
Water pollutants(ppm) COD Legal limit 90 Average 8.4
Water pollutants(ppm) SS Legal limit 80 Average 3.9

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building251,240
  • Pavement449,587
  • Green59,504
Person in charge
  • Personnel : Dongju Song
  • E-mail : dj1212.song@samsung.com
  • TEL : +82-70-7092-6281
Ulsan

단위 : 명

  • building33.0
  • Pavement59.1
  • Green7.8
  • Area Unit(Unit: ㎡)
    • building : 251,240
      Pavement : 449,587
      Green : 59,504
  • Person in charge
    • Personnel : Dongju Song
      E-mail : dj1212.song@samsung.com
      TEL : +82-70-7092-6281
Location

Situated within an industrial complex technically. Residential areas are nearby. Mt. Sinbul, called Korea southern Alps, is in the back. After being treated with biological and chemical methods, the final discharge joins the Sangchun stream, the upstream of the Taehwa river, and moves along the river to the East sea.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 4,713
Water(kiloton) : 1,604
Recycle Water(kiloton) : 346
Toxic chemicals(ton) : 7,950
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 208
Water discharge(kiloton) : 1,864
Waste Recycling(ton) : 14,727
Waste Landfill(ton) : 422
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 200 Average 2.0
Air pollutants(ppm, mg/㎥) SOx Legal limit 500 Average 0.6
Air pollutants(ppm, mg/㎥) Dust Legal limit 100 Average 3.6
Air pollutants(ppm, mg/㎥) HF Legal limit 3 Average 0.2
Air pollutants(ppm, mg/㎥) HCI Legal limit 6 Average 0.4
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 10 Average 0.9
Water pollutants(ppm) COD Legal limit 40 Average 4.6
Water pollutants(ppm) SS Legal limit 10 Average 0.7

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building101,772
  • Pavement46,985
  • Green76,629
Person in charge
  • Personnel : Zhenguo Zhang
  • E-mail : zhguo.zhang@samsung.com
  • TEL : +86-22-8212-9971
Tianjin (TSDI)

단위 : 명

  • building47.0
  • Pavement20.1
  • Green32.8
  • Area Unit(Unit: ㎡)
    • building : 101,772
      Pavement : 46,985
      Green : 76,629
  • Person in charge
    • Personnel : Zhenguo Zhang
      E-mail : zhguo.zhang@samsung.com
      TEL : +86-22-8212-9971
Location

Technically situated within the TEDA industrial development area. It is 1.5km away from nearest residential areas. The Won stream runs 4km from the site. The plant runs chemical treatments for company sewage. Water discharge moves to the sewerage treatment facility in Ilsun industrial complex.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 1.455
Water(kiloton) : 645
Recycle Water(kiloton) : 0
Toxic chemicals(ton) : 37
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 148
Water discharge(kiloton) : 224
Waste Recycling(ton) : 2,474
Waste Landfill(ton) : 0
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), 법기준, 년평균
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) Dust Legal limit 10 Average 1.2
Air pollutants(ppm, mg/㎥) Foul smell Legal limit 1,000 Average 219.5
Air pollutants(ppm, mg/㎥) HCI Legal limit 22 Average 1.7
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 300 Average 38.6
Water pollutants(ppm) COD Legal limit 150 Average 36.8
Water pollutants(ppm) SS Legal limit 140 Average 12.0

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building84,123
  • Pavement61,101
  • Green149,993
Person in charge
  • Personnel : MASKHAIRIAH ISMAIL
  • E-mail : khariah.is@samsung.com
  • TEL : +60-670-1358-8
Malaysia (SDIEM)

단위 : 명

  • building28.5
  • Pavement20.7
  • Green50.8
  • Area Unit(Unit: ㎡)
    • building : 84,123
      Pavement : 61,101
      Green : 149,993
  • Person in charge
    • Personnel : MASKHAIRIAH ISMAIL
      E-mail : khariah.is@samsung.com
      TEL : +60-670-1358-8
Location

Situated in industrial areas 3km away from nearest residential area. Mt. Angsi is 2km to the east and River Simin runs to the west of the plnat.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 1,702
Water(kiloton) : 836
Recycle Water(kiloton) : 0
Toxic chemicals(ton) : 123
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 85
Water discharge(kiloton) : 201
Waste Recycling(ton) : 731
Waste Landfill(ton) : 106
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 2 Average 0.02
Air pollutants(ppm, mg/㎥) SOx Legal limit 0.2 Average N/A
Air pollutants(ppm, mg/㎥) Dust Legal limit 0.4 Average 0.01
Compliance with environmental laws and regulations - Water pollutants(ppm), Legal limit, Average
Water pollutants(ppm) Legal limit Average
Water pollutants(ppm) BOD Legal limit 50 Average 33
Water pollutants(ppm) COD Legal limit 200 Average 142

The data calculation period is from January 1st 2014 to December 31st.

Samsung SDI Environment Management Plants status
Area Unit(Unit: ㎡)
  • building14,509
  • Pavement7,705
  • Green1,230
Person in charge
  • Personnel : Ms. Vu Thi Thuy
  • E-mail : thuy.vt@samsung.com
  • TEL : +84-241-626-2149
Vietnam (SDIV)

단위 : 명

  • building61.9
  • Pavement32.9
  • Green5.2
  • Area Unit(Unit: ㎡)
    • building : 14,509
      Pavement : 7,705
      Green : 1,230
  • Person in charge
    • Personnel : Ms. Vu Thi Thuy
      E-mail : thuy.vt@samsung.com
      TEL : +84-241-626-2149
Location

SDIV located in Yen Phong 1 industrial zone. The east, west, north, of SDIV is SEV company(0.3km away) and empty land. The south is field, highway far away 0.5km. SDIV have only sewage water(no industrial waste water). Sewage water is treated preliminary by septic tank. After that, it flows into and treated by the waste water system of Samsung Electronics Vietnam.

Present status of resources use and discharge
Present status of resources use and discharge - INPUT
INPUT
Energy (TJ) : 116
Water(kiloton) : 33,641
Recycle Water(kiloton) : 0
Toxic chemicals(ton) : 0
Present status of resources use and discharge - OUTPUT
OUTPUT
Greenhouse : 5,399
Water discharge(kiloton) : 26,913
Waste Recycling(ton) : 223
Waste Landfill(ton) : 351
Compliance with environmental laws and regulations
Compliance with environmental laws and regulations - Air pollutants(ppm, mg/㎥), Legal limit, Average
Air pollutants(ppm, mg/㎥) Legal limit Average
Air pollutants(ppm, mg/㎥) NOx Legal limit 850 Average 0.22
Air pollutants(ppm, mg/㎥) SOx Legal limit 500 Average 0.2
Air pollutants(ppm, mg/㎥) Dust Legal limit 200 Average 0.1
Air pollutants(ppm, mg/㎥) CO Legal limit 1,000 Average 2.0

The data calculation period is from January 1st 2014 to December 31st.